IC-706(無印)VHF帯感度測定 処置後 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
測定条件:12dB-SINAD感度 |
|
|
|
|
|
|
MODE
= FM-Narrow |
|
|
|
|
|
周波数偏移 = 最大±5kHz機の70%変調で測定 =
±3.5kHz |
|
|
|
|
AMP-off |
AMP-ON |
|
測定周波数は、各MHzの25kHz上(例:144MHzの場合・144.025MHz、146MHzのみ25kHz下) |
|
|
|
MHz |
dBuV |
dBuV |
|
|
|
108 |
-1.8 |
-9.6 |
|
|
|
109 |
-1.6 |
-9.4 |
|
|
110 |
-1.4 |
-9.4 |
|
|
111 |
-1.1 |
-9.5 |
|
|
112 |
-1.0
|
-9.5 |
|
|
113 |
-1.0
|
-9.6 |
|
|
114 |
-0.4 |
-9.2 |
|
|
115 |
-0.2 |
-8.7 |
|
|
116 |
-0.2 |
-9.6 |
|
|
117 |
0.0
|
-9.6 |
|
|
118 |
0.1 |
-9.7 |
|
|
119 |
0.4 |
-9.3 |
|
|
120 |
0.2 |
-7.8 |
|
|
121 |
0.3 |
-9.9 |
|
|
122 |
0.4 |
-9.7 |
|
|
123 |
0.3 |
-9.0
|
|
|
124 |
0.3 |
-9.2 |
|
|
125 |
0.4 |
-8.3 |
|
|
126 |
0.4 |
-9.4 |
|
|
127 |
0.4 |
-9.0
|
|
|
128 |
0.4 |
-9.6 |
|
|
129 |
1.2 |
-6.7 |
|
|
130 |
0.6 |
-9.7 |
|
|
131 |
0.6 |
-9.3 |
|
|
132 |
0.9 |
-9.3 |
|
|
133 |
0.8 |
-9.4 |
|
|
134 |
0.8 |
-9.1 |
|
|
135 |
1.0
|
-9.0
|
|
|
136 |
1.0
|
-9.1 |
|
|
137 |
1.1 |
-8.8 |
|
|
138 |
1.1 |
-8.8 |
|
|
139 |
1.2 |
-8.0
|
|
|
140 |
1.3 |
-8.4 |
|
|
141 |
1.1 |
-8.4 |
|
|
142 |
1.3 |
-8.1 |
|
|
143 |
1.4 |
-7.7 |
|
|
144 |
-0.7 |
-8.3 |
|
|
145 |
-1.0
|
-8.8 |
|
|
146 |
-1.0
|
-8.4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|